4.11.1 Optional Thrust Base Assembly Removal.

Step 1

Remove the four (4) screws (# ) and remove the thrust base subassembly (#16-17) by sliding the base down. If base
is ISO remove the spacer (pilot) (#16-16).

Step 2

Remove the four (4) screws (# 16-15) and remove the adapter plate (#16-14) and torque nut (#16-10). Item (#16-11)
bushing is pressed into adapter plate and cannot be removed. The torque nut is held in place by the unit drive sleeve
and the bushing (#16-11).

Table 4.24 Optional Thrust Base Subassembly

ITEM NUMBER

DESCRIPTION

QTY.

10-1

HOUSING, THRUST BASE

1

10-2

PILOT, THRUST BASE

1

10-3

THRUST NUT

1

10-6

SOCKET HEAD CAP SCREWS

1

10-7

FLAT WASHER

1

10-8

RELIEF FITTING

1

10-10

SOCKET HEAD CAP SCREWS

4

10-11

GREASE FITTING

1

10-12

NEEDLE BEARING

2

10-13

THRUST RACE

2

10-14

QUAD RING

1

10-15

O'-RING

1

10-16

QUAD RING

1

Figure 4.28 - Optional Thrust Base Subassembly