Flowserve QX Limitorque User Manual

Page 47

Advertising
background image

47

Limitorque QX Electronic Actuator FCD LMENIM3314-00 – 5/11

flowserve.com

4.11.2 Thrust Base Remounting.

Step 1

Place QX torque nut (#16-10) into unit drive sleeve (#1-11) aligning nut lugs to drive sleeve slots.

Step 2

Lightly lubricate ‘O’-rings (#16-12) and (#16-13) and insert into bushing (#16-11) that is pressed into adapter plate

(#16-14). Slide adapter plate and bushing over end of torque nut and aligning to unit baseplate. Insert screws (#16-15)
into adapter plate holes and tighten.

Step 3

Align thrust base subassembly nut lugs (#10-3) with QX torque nut (#16-10) slots and slide thrust base on to QX
unit baseplate aligning pilots. Note; For ISO thrust base pilot spacer (#16-16) must be used to align thrust base to QX
baseplate. Insert screws (#10-10) into thrust base holes and tighten.