Limitorque MX Maintenance and Spare Parts FCD LMENIM2314-00 – 07/08

128

STEP 17

Install the control cover and the mounting screws.

STEP 18

Complete by following Step 9 in Section 5.10.

5.12 19 Amp Power Assembly for Units Shipped

After September 2007

Table 5.9 – 19 Amp Power Assembly

Part Number

Description

Qty.

1-19

Controls Assembly

1

8-3

Power Board

1

8-7

Mounting Plate Screws

3

8-10

Screws

3

8-12

Shield

1

5.12.1 Removal

STEP 1

Remove the ACP controls cover assembly

8-3

8-12

8-10

1

STEP 2

Disconnect all connectors to power board (8-3)
Remove the three screws (8-10) and shield (8-12).

STEP 3

Disconnect the three power board wires from
l1, l2 and l3 on reverser as shown by loosening
the reverser screws and remove the power
board.

STEP 3

DISCONNECT THE 3 POWER BOARD WIRES FROM L1, L2 AND L3 ON

REVERSER AS SHOWN BY LOOSENING THE REVERSER SCREWS AND

REMOVE THE POWER BOARD.

DISCONNECT THE 3 TERMINAL BLOCK WIRES FROM L1, L2 AND L3 ON

REVERSER AS SHOWN BY LOOSENING THE REVERSER SCREWS.

STEP 4

19 AMP POWER ASSEMBLY REMOVAL 2

19 AMP POWER ASSEMBLY REMOUNTING

FROM TERMINAL BLOCK LI (BLACK WIRE)

TO L1 CONTACTOR
FROM TERMINAL BLOCK L2 (LIGHT BLUE WIRE)

TO L2 CONTACTOR
FROM TERMINAL BLOCK L3 (BROWN WIRE)

TO L3 CONTACTOR

TO CONTACTOR

LI (BLACK WIRE) TO L1 CONTACTOR

L2(LIGHT BLUE WIRE) TO L2 CONTACTOR

L3 (BROWN WIRE) TO L3 CONTACTOR

TO MOTOR

TWO WHITE 2-PIN

CONNECTORS NOT SHOWN

1-19

8-3

REVERSER

HOUSING NOT SHOWN FOR CLARITY

REMOUNT 19AMP POWER ASSEMBLY BY REVERSING THE STEPS FOR REMOVAL.