4 remounting – Flowserve MX Limitorque User Manual

Page 47

Advertising
background image

39

Limitorque MX Maintenance and Spare Parts FCD LMENIM2314-00 – 07/08

flowserve.com

4.4.4 Remounting

STEP 4

Check that bearing (#13-8) is correctly in place
in the actuator housing.

The MX-10 and -20 is a slip fit (4a).

The MX-85, -140, and -150 is a press fit (4b).

4a

13-8

4b

STEP 5

Insert the complete subassembly into the
actuator housing, rotating counterclockwise
(CCW) to properly mesh the gearing. Ensure
the end of the worm shaft is seated in the inner
bearing (#13-8).

5

STEP 6

Position the worm shaft cap (#13-2) back on
the actuator housing. Using a 6 mm hex key, fit
the (#13-9) screws onto the worm shaft cap to
secure side-mounted assembly to the actuator
housing.

6

Advertising