2 remounting – Flowserve MX Limitorque User Manual

Page 70

Advertising
background image

Limitorque MX Maintenance and Spare Parts FCD LMENIM2314-00 – 07/08

62

4.9.2 Remounting

STEP 3

a

CAUTION: To ensure actuator is fully secured on mounting plate, ensure baseplate (#11-1)
is tightened with the following torque values on mounting screws (#11-5):

MX-05 and -10 = 12 ft-lb (16 N m)

MX-20 and -40 = 24 ft-lb (32 N m)

MX-85, -140, and -150 = 90 ft-lb (114 N m)

Lightly lubricate the outside of the drive sleeve,
the quad ring or seal (#11-3), and O-ring
(#11-4) before remounting baseplate.

3

11-3

11-4

STEP 4

NOTE: (MX-20 only) Match outer bosses of baseplate with outer bosses of actuator housing before
mounting baseplate assembly.

NOTE: (MX-85, -140, and -150) Match mounting holes in baseplate to housing taps. Baseplate and
housing has one hole/tap that is not equally spaced.

Carefully push the baseplate assembly onto the
end of the drive sleeve, ensuring that the quad
ring or seal (#11-3) is not damaged. Align the
mounting holes and secure the baseplate with
the screws (#11-5).

4

Advertising