Limitorque MX Maintenance and Spare Parts FCD LMENIM2314-00 – 07/08

24

Figure 4.3 – Motor, Support Plate and Adapter (MX-150)

UNIT HOUSING

1-15

4-8

4-13

4-15

4-7

4-9

4-16

4-10

4-14

4-11

4-18

4-17

4-19

4-20

4-20

UNIT BASEPLATE

UNIT BASEPLATE

MOUNT ADAPTER (PC-4-8) TO UNIT HOUSING

BEFORE MOUNTING MOTOR (PC-4-7)

STEP 1

Install support plate (4-17) to unit base plate using socket head cap screws (#4-20).

STEP 2

Place the lead seal connector through the slot in the adapter (#4-8). Install the adapter loosely to unit
housing using screws (#4-15). Rotate adapter until gap is uniform with plate (#4-17). Tighten screws
(#4-15).

STEP 3

Measure gap and select the shim (#4-18) total thickness to be at least the gap plus up to .1mm (.004
inch). Shims are .1mm (.004 inch) each.

STEP 4

Remove plate (#4-17), install shims (#4-18), reinstall plate to base of unit, tighten screws (#4-20). Then
install and tighten screws (#4-19) with shims in place.

NOTES:

1. Pipe plugs (#4-16) must be installed with tape or pipe sealant over the four (4) mounting screws
(#4-15) and the two (2) jacking tap holes.

2. When mounting motor (#4-7) leads must be placed behind plate (#4-13).