2 remounting (type b1/b4/b4e base) – Flowserve MX Limitorque User Manual

Page 20

Advertising
background image

Limitorque MX Maintenance and Spare Parts FCD LMENIM2314-00 – 07/08

12

STEP 2

c

WARNING: Potential high-pressure vessel! Before disassembling your actuator,
ensure that the valve or other actuated device is isolated and is not under pressure.

Lift actuator from mounting adapter.

2

3.1.2 Remounting (Type B1/B4/B4E Base)

STEP 3

Ensure stem nut (#1-22) is secured inside
actuator drive sleeve with retaining ring
(#1-23). Lower the actuator onto the mating
component, making sure to align stem nut key
and keyway with mating component.

3

1-22

1-23

STEP 4

Ensure that the actuator and mounting adapter
flange mating holes are aligned correctly.

4

Advertising