15

5.2.3 Twisted pair cable for extension

The connector for a long-haul transmission is the same as the 8-core modular connector that is used for

Ethernet. However, it cannot connect to Ethernet since the transmission method is not the same.

To ensure the best performance, select and connect the proper twisted pair cable correctly.

● We recommend a Cat6 UTP/STP cable for the twisted pair cable between the transmitter and receiver.

If using an STP cable, connect the FG connector to a ground source. Otherwise, the shielding feature
does not work correctly. When using a UTP cable, we still recommend using the ground connector.

● For 50 m/ 164.04 feet or shorter transmissions, Cat5e UTP cable can be used.

● The shielded STP cables are less affected by interference or external noise than UTP cables.

● The maximum extension distance of Cat5e/Cat6 UTP/STP cable is the shortest distance of maximum

extension distances of HDC transmitter, HDC receiver and sink device.

● For pin assignments apply T568A or T568B standards for straight through cabling.

● Do not give connection cables a strong pull. The allowable tension of the twisted pair cable is 110 N.

● Do not bend the connection cable at a sharp angle. Keep the bend radius four times of the cable diameter

or larger.

● Do not tie the cable tightly; leave a space allowing the cable to move slightly.

● If you use the same cables, we recommended keeping a distance between the cables or not to place

the cables closely in parallel.

● Keep the twisted pair cable as straight as you can. If you coil the cable, it is easily affected by noise.

● Do not place this product in an electrically noisy environment, since high-speed signals are transmitted.

Particularly when you use a high-output radio around the HDC, video or audio may be interrupted.

● If the distance between the transmitter and receiver is 100 m/328.08 feet or less, cables can be joined

using an RJ-45 plug coupler or wall outlet. Up to two cable couplers are allowed and couplers supporting
Cat6A (10GBase-T) are recommended.

● The table below shows supported extension distance for each twisted pair cable category. Note that the

distance may shorten depending on the actual environment.

Category

Extension

distance

Dot clock

Remarks

Cat5e

50 m/164.04 ft.

<=225 MHz

For 50 m/164.04 ft. or longer, Cat6 is

recommended

Cat6

100 m/328.08 ft.

70 m/229.66 ft.

>225 MHz

(4K format)

For 70 m/229.66 ft. or longer, Cat6 STP/Cat5e

STP is recommended

Cat5eSTP
Cat6STP

100 m/328.08 ft.

Note: If there is a problem in the transmission path, video or audio may be interrupted. Please check the

items above. If the problem still cannot be solved, shorten the length of the twisted pair cable.

5.2.4 Precautions for RS-232C communication

When designing a control program, please note the following points:

● For RS-232C communication, unnecessary data may be input to RS-232C signals when the HDC is

turned off or the link is established.

● The control by RS-232C communication is not available until the link is established.