8.2 System settings 0x2000 - 0x207F)

Index

Type

Value

Unit

R/W

Reset

0x2000

UNSIGNED8

Device address

default 25

R/W

X

0x2001

UNSIGNED16

Baud rate

default 250

Kbit

R

X

0x2002

UNSIGNED8

Flag to reset MC
flag = 1

MC reset

R/W

0x2040

UNSIGNED8

Flag for quadrant correction
0: off
1: on

± 180°

2: on

0° - 360°

R/W

0x2041

UNSIGNED8

Flag for heating
flag = 0

heating off

flag = 1

heating on

R/W

0x2042

UNSIGNED8

Index for teach values

of the X/Y/Z axes
0: no change
1: set teach, relative

measurement
2: reset teach, absolute

measurement

R/W

0x2043

UNSIGNED8

FIR filter step for angle

measurement

0 : FIR deactivated
1 : FIR lowpass 10Hz
2 : FIR lowpass 5Hz
3 : FIR lowpass 1Hz
4 : FIR lowpass 0�5Hz

R/W

0x2044

UNSIGNED8

Angle calculation
0: perpendicular
1: Euler
2: gimbal 1X
3: gimbal 1Y

R/W

0x2045

UNSIGNED8

CAN 120 Ohm terminating

resistor
0: resistor deactivated
1: resistor activated

R/W