ifm electronic JN2300 User Manual

Page 14

Advertising
background image

Inclination sensor JN

14

Index

Type

Value

Unit

R/W

Reset

0x2046

UNSIGNED8

Set index for zero of the
X / Y / Z axes
0: no change
1: activate set zero; relative

measurement
2: reset set zero; absolute

measurement

R/W

0x2047

UNSIGNED8

Output value
0: angle
1: v eff (v effective) and a peak

(a peak)
2: aVector X / Y / Z

without DC part
3: aVector X / Y / Z

with DC part

automatic selection of

measuring range ± 2 g

R/W

0x2048

UNSIGNED8

Axis selection
v eff / a peak
X axis active

bit 2 = 1

X axis not active

bit 2 = 0

Y axis active

bit 1 = 1

Y axis not active

bit 1 = 0

Z axis active

bit 0 = 1

Z axis not active

bit 0 = 0

R/W

0x2049

UNSIGNED8

FIR filter step for
v eff / a peak measurement
0 : FIR deactivated
1 : FIR bandpass filter 0�1���1

Hz
2 : FIR bandpass filter 0�1���10

Hz
3 : FIR bandpass filter 1���10 Hz
4 : FIR bandpass filter 2���400

Hz
5 : FIR bandpass filter 10���400

Hz

R/W

0x204A

UNSIGNED8

Measuring range for v eff /

a peak measurement and

acceleration
0: ± 2 g
1: ± 4 g
2: ± 8 g

R/W