1 informative (0x2080 – 0x2082), 2 upload/download (0x3000), 3 measured data (0xa000 – 0xa011) – ifm electronic JN2300 User Manual

Page 15: 4 additional functionality (0xa100 xa202)

Advertising
background image

UK

Inclination sensor JN

15

Index

Type

Value

Unit

R/W

Reset

0x207F

UNSIGNED8

Factory reset
1: make factory reset

R/W

8.2.1 Informative (0x2080 – 0x2082)

Index

Type

Value

Unit

R/W

Reset

0x2080

INTEGER16

Ambient temperature

1/10 °C

R

0x2081

INTEGER16

MEMS temperature

1/10 °C

R

0x2082

UNSIGNED16

Heating power

mW

R

8.2.2 Upload/download (0x3000)

0x3000

ASCII

Programming key

R/W

8.2.3 Measured data (0xA000 – 0xA011)

0xA000

INTEGER16

Longitudinal X axis

°

R

0xA001

INTEGER16

Lateral Y axis

°

R

0xA010

INTEGER32

Longitudinal X axis

°

R

0XA011

INTEGER32

Lateral Y axis

°

R

8.2.4 Additional functionality (0xA100...0xA202)

0xA100

UNSIGNED32

v effective vector

1/10 mm/s

R

0xA101

UNSIGNED32

a peak vector

mg

R

0xA200

INTEGER16

aVector X axis

mg

R

0xA201

INTEGER16

aVector Y axis

mg

R

0XA202

INTEGER16

aVector Z axis

mg

R