ilve Built-in Cooktop User Manual

Page 23

Advertising
background image

Burners, Injectors & Mega-joules

AIR ADJUSTMENT

The air adjustment is to be carried out with the flame at the maximum, with a screwdriver loosen screw

“F” and move the cylindrical sleeve “R” towards the injector to decrease the air, move it away from the

injector to increase the air. Once the correct aeration is achieved tighten screw “F” to fix the position.

BURNER

NATURAL GAS

Inj Mj/h Kpa

ULPG

Inj Mj/h Kpa

DUAL WOK

1.60/0.68 14/2.2

1.00

0.86/.040 11.5/2

2.75

SINGLE WOK

1.70

13.8

1.00

0.92

11.00

2.75

LARGE

1.40

10.0

1.00

0.82

9.00

2.75

MEDIUM

1.10

6.2

1.00

0.68

6.00

2.75

FISH / TEPANYAKI

1.60

12.5

1.00

0.85

10.00

2.75

Buil

t-in cooktops

23

ILVE Built-in Cooktop Operating & Installation Manual