31

5.4 No Cap Check

The NO CAP CHECK option allows you to enable or disable whether the USB Duplicator checks the

capacity between the Source and Target(s). Tap the ‘RUN’ button to change this option.

• [

٭

] – Enabled. When the duplicator executes either a Disk Copy or Brief Copy, the Kanguru USB

Duplicator will not check the capacity between the Source and Target(s) and the copy process will

begin normally.

• [ ] – Disabled (default). When the duplicator executes either a Disk Copy or Brief Copy, the

Kanguru USB Duplicator checks the capacity between the Source and Target(s). If the capacity

between the Source and Target(s) is different, then the system will automatically cancel the copy

process.

5.5 Max UDMA Mode

The MAX UDMA MODE option allows you to configure the transfer speed specification for the Kanguru

USB Duplicator’s internal hard drive. Tap the ‘RUN’ button to change this option. The MAX UDMA

MODE can be set as 0 – 5. The MAX UDMA MODE is set to 4 by default.

5.6 Burn In

The BURN IN function allows the system to perform a Copy, Compare, Verify, Erase or Load function

continuously to stress test for endurance, reliability and stability.

To perform a continuous burn in test:

1. From the ADVANCED SETUP menu, tap the ‘SET’ button to navigate to the BURN IN option.

2. The BURN IN option is disabled by default. Tap the ‘RUN’ button to enable it.

3. Hold the ‘SET’ button to return to the SETUP menu.

4. From the SETUP menu, hold the ‘SET’ button to return to the Main menu.

5. Tap the ‘SET’ button to navigate to the mode that you want to test. The screen will display:

“READY TO BURN 30…”.

6. Tap the ‘RUN’ button to begin the burn in test, or wait for the “30” to count down to “0” and the

burn in test will start automatically.

7. Once the function has completed, The screen will display the total execution time, and then it will

once again display “READY TO BURN 30…”. When it counts down to zero the function will start

again. This will be repeated until you stop the burn in test.

8. To stop the burn in test, cancel a function while it is in progress by tapping either the ‘SET’ button

or ‘RUN’ button. This will automatically disable the burn in function and the USB Duplicator will

return to normal functionality.