83

4.2.14 Error No. (Output)

(1) Function

When an error occurs, the signal outputs the error number in a 3-digit (12-

bit) hexadecimal code.

(2) Terminal numbers

No.17 to No.28 of connector CN10.

(3) Usage

The signal is used to display an error number on the external device.

(4) Output conditions

The signal will be output when an error occurs.

(5) Clear conditions

The signal will be cleared when CLEAR ROBOT FAILURE and
OPERATION PREPARATION START signals are inputted or by operating
the Cancel key of the operating panel or the teach pendant. When this
signal is cleared, all states will become OFF (0).

(6) Hexadecimal codes

See the following figure.

ЧЧЧЧ

0

Ч

¡

Ч

¡

5

¡

Ч

¡

Ч →

A

ЧЧЧ

¡

1

Ч

¡¡

Ч →

6

¡

Ч

¡¡

B

ЧЧ

¡

Ч →

2

Ч

¡¡¡

7

¡¡

ЧЧ →

C

ЧЧ

¡¡

3

¡

ЧЧЧ →

8

¡¡

Ч

¡

D

Ч

¡

ЧЧ →

4

¡

ЧЧ

¡

9

¡¡¡

Ч →

E

¡

⋅⋅⋅

ON

¡¡¡¡

F

×⋅⋅⋅⋅

OFF

Hexadecimal Codes

The figure below shows an example of error number output, when
ERROR174 (overload error with the fourth axis) occurs.

28 27

26 25

24 23

22 21

20

19 18

17

Terminal No.

(connector CN10)

Example of Error Number Output

Hundreds of error No.

Tens of error No.

Units of error No.