Step stop (all tasks) (input), 3 step stop (all tasks) (input) – Denso RC5 User Manual

Page 61

Advertising
background image

41

3.4.3 Step Stop (All Tasks) (Input)

(1) Function

Input this signal to step-stop the program being executed from the
external device. All tasks will be step-stopped.

(2) Terminal

No.5 of connector CN8.

(3) Input conditions and operation

 If the state of this signal is changed from ON (shorted) to OFF (open),

the robot will stop all tasks as soon as the ongoing step is completed,
and the Robot-in-operation signal will be turned OFF. However, auto
mode or external mode will remain valid, and the suspended program
will be resumed by inputting a program operation command (start). See
the figure given below.

‚ For resuming the program after a step stop, see Chapter 5, Subsection

5.3.2 "Program Operation Command (0001)".

Step Stop Signal

Robot status

1-cycle operation

Operating halfway

At step-stop

Performing

Remaining operation

Program start signal (input)

ON (shorted)
OFF (open)

Step-stop signal (input)

ON (shorted)
OFF (open)

Robot-in-operation (output)

ON (shorted)
OFF (open)

Advertising