I/o commands details – Denso RC5 User Manual

Page 72

Advertising
background image

52

3.5.3 I/O Commands Details

3.5.3.1

List of I/O Commands

The table below lists I/O commands.

List of I/O Commands

Command area

Data area 1

Data area 2

Status area

0001

Program operation

00000001 Program reset start

00000010 Program start

00000100 Continue start

00010000 Step stop

00100000 Instantaneous stop

01000000 Reset

Program number

Program number

(Note)

Program number

Program number

Program number




0010

External speed and
acceleration setting

00000001 Speed setting

00000010 Acceleration setting

00000100 Deceleration setting

Set speed value

Set acceleration
value

Set deceleration
value



0100

Error read

Error
number

0101

Type I variable
write

Type I variable number

Set variable value
(lower 16 bits)

0110

Type I variable read

Type I variable number

Variable
value (lower
16 bits)

0111

Mode switching

00000001 Motor ON, CAL execution

00000010 External speed 100

10000000 External mode switching

10000011 Execution of all above

(Motor ON

CAL

SP100

External)

1000

Clear robot failure

1001

I/O write

Set I/O value

First internal I/O port
address

1010

I/O read

First internal I/O port
address

I/O

(Note) In execution of Continue Start command, program numbers will be ignored.

Advertising