POSITIONING THE REMOTE TEMPERATURE TRANSMITTER:

The remote temperature transmitter can be placed onto any flat surface or wall
mounted using the bracket which doubles as a stand or wall mount base.







To wall mount:
1.

Secure the bracket onto a desired wall using the screws and plastic
anchors.

2.

Clip the remote temperature transmitter onto the bracket.

Note:
The mounting surface can affect the transmission range. If, for instance, the unit
is attached to a piece of metal, it may then either reduce or increase the
transmitting range. For this reason, we recommend not to place the unit on any
metal surfaces or in any position where a large metal or highly polished surface
is in the immediate vicinity (garage doors, double glazing, etc.). Before securing

18

in place, please ensure that the Temperature Station can receive the 915MHz signal from the
temperature transmitter at the positions that you wish to place them.

CARE AND MAINTENANCE:

Extreme temperatures, vibrations and shocks should be avoided as these may cause damage to
the unit and give inaccurate forecasts and readings.

When cleaning the display and casings, use a soft damp cloth only. Do not use solvents or
scouring agents as they may mark the LCD and casings.

Do not submerge the units in water. Furthermore, fix all parts in place where the units are
adequately protected against moisture and rain.

Immediately remove all low powered batteries to avoid leakage and damage. Replace only with
new batteries of the recommended type.

Do not make any repair attempts to the unit. Return them to their original point of purchase for
repair by a qualified engineer. Opening and tampering with the unit may invalidate their
guarantee.

Do not expose the units to extreme and sudden temperature changes, this may lead to rapid
changes in forecasts and readings and thereby reduce their accuracy.

SPECIFICATIONS:

Temperature measuring range
Indoor

:

-3.8ºF to +139.8ºF with 0.2ºF resolution

(-19.9 to +59.9

C with 0.1C resolution)

(“OF.L” displayed if outside this range)

19

Outdoor

:

-39.8ºF to +139.8ºF with 0.2ºF resolution

(-39.9 to +59.9

C with 0.1C resolution)

(“OF.L” displayed if outside this range)

Indoor Temperature checking interval :

every 20 seconds

Outdoor data checking interval

:

every 4 seconds

Power consumption
Temperature Station

:

3 x AA, IEC LR6, 1.5V

Outdoor Temperature Transmitter

:

2 x AAA, IEC LR3, 1.5V

Battery life cycle (Alkaline batteries recommended):

Temperature Station

:

approximately 24 months

Outdoor Temperature Transmitter

:

approximately 12 months

Dimensions (L x W x H)
Temperature Station

:

3.58” x 1.14” x 5.90” / 91 x 29 x 150 mm

Outdoor Temperature Transmitter

:

1.27" x 0.55" x 3.40" / 32.4mm x

14.1 x 86.5mm

WARRANTY

La Crosse Technology, Ltd provides a 1-year limited warranty on this product against manufacturing
defects in materials and workmanship.

This limited warranty begins on the original date of purchase, is valid only on products purchased and
used in North America and only to the original purchaser of this product. To receive warranty service,
the purchaser must contact La Crosse Technology, Ltd for problem determination and service
procedures. Warranty service can only be performed by a La Crosse Technology, Ltd authorized

20

service center. The original dated bill of sale must be presented upon request as proof of purchase to
La Crosse Technology, Ltd or La Crosse Technology, Ltd’s authorized service center.

La Crosse Technology, Ltd will repair or replace this product, at our option and at no charge as
stipulated herein, with new or reconditioned parts or products if found to be defective during the limited
warranty period specified above. All replaced parts and products become the property of La Crosse
Technology, Ltd and must be returned to La Crosse Technology, Ltd. Replacement parts and
products assume the remaining original warranty, or ninety (90) days, whichever is longer. La Crosse
Technology, Ltd will pay all expenses for labor and materials for all repairs covered by this warranty. If
necessary repairs are not covered by this warranty, or if a product is examined which is not in need or
repair, you will be charged for the repairs or examination. The owner must pay any shipping charges
incurred in getting your La Crosse Technology, Ltd product to a La Crosse Technology, Ltd authorized
service center. La Crosse Technology, Ltd will pay ground return shipping charges to the owner of the
product to a USA address only.

Your La Crosse Technology, Ltd warranty covers all defects in material and workmanship with the
following specified exceptions: (1) damage caused by accident, unreasonable use or neglect (including
the lack of reasonable and necessary maintenance); (2) damage occurring during shipment (claims
must be presented to the carrier); (3) damage to, or deterioration of, any accessory or decorative
surface; (4) damage resulting from failure to follow instructions contained in your owner’s manual; (5)
damage resulting from the performance of repairs or alterations by someone other than an authorized
La Crosse Technology, Ltd authorized service center; (6) units used for other than home use (7)
applications and uses that this product was not intended or (8) the products inability to receive a signal