FINAL WIRING CHECKLIST BEFORE POWERING UP SYSTEM

Have you checked all home runs?

Have you checked all wiring between floors (risers)?

Are you sure all grounds are properly tied between Emerald OPs?

Have you made sure all Data and Audio and Speaker wires are tested and installed?

Check polarity of all wiring throughout, especially power cables. If continuity is

reversed at any point, some or all of the Emerald OPs will be irreversibly damaged.

NEVER WORK WITH POWER WIRE, OR CONNECT POWER WIRES TO

EMERALD OPs, WHILE POWER IS ON.

2

4

5

1

3

TIP

TIP! Check data wires

by going to the Sound

Manager Configurator and

refreshing Emerald OPs

after each Emerald OP
is connected. This will
help to eliminate large

trouble shooting issues

at the end of the job.

WARNING

NEVER WIRE or CONNECT

POWER TO AN EMERALD

OP WHILE POWER IS ON!!!

EMERALD OP will lose its

number identity. Always

connect wire to EMERALD OP

while power supply is

not plugged in.