3.5 TOUCH SCREEN CONTROL PANEL

The APS uses a colour LCD touch screen which is operated by touching the virtual buttons
with your finger or a stylus.

Home Screen



The output channel status indicators at the top of the home screen show the current status
of each output:

Green

= The channel is On.

Red

= The channel is Off.

Orange

= The channel has been automatically turned “Off” due to an under voltage

or over voltage input but the input voltage is now within limits and the channel is
about to automatically turn back on after it’s staggered start up time delay.


The “Input Voltage High Limit” and “Input Voltage Low Limit” per phase can be set. If these
limits are exceeded, the outputs connected to that phase will be switched off and their
status indicators on the home screen will turn

red

. See section 4.5.


The input current per phase is displayed in

green

. The readout turns

orange

as a warning

when the input current reaches 90% of the maximum allowable current per phase. Note
that this reading is the total input current per phase. The maximum current per output
channel is determined by the capacity of its front panel RCBO circuit breaker.

The DMX status is

green

when DMX is present and flashes

red

when DMX is not present.

See section 2.4.2.

The GPI status is

green

when a GPI signal (contact closure) is present. See section 2.4.4


If the outputs are manually turned off from the touch screen (Manual Off), then the DMX
and GPI status indicators are replaced by a “Manual Mode” indicator. See section 4.6

Output Channel Status

Green = On

Red = Off

Orange = see below

Input Voltage per phase

Green = OK

Red = over/under limit

Input Current per phase

Green = OK

Orange = 90% load

warning

DMX Status

Green = Present

Flashing Red = Missing

Input

frequency

Input Voltage High Limit

per phase

Input Voltage Low Limit

per phase

GPI Status

Green = ON

Manual Mode