Note: In Standalone mode, stagger time is fixed. See section 4.7.1

4.4.2

Power Off Delay

Power off delay is the time that the outputs stay on when either DMX is lost or the GPI input
contact closure is opened. The range is 1 to 60 minutes or infinite. The default time is 5
minutes. To change the power off delay touch Edit.


If the DMX signal is lost or the GPI input contact closure is opened, the countdown to power
off begins. When it reaches 30 seconds the “warning beep” sounds (if enabled) and a warning
appears on the screen and counts down the remaining time to switch off. The warning beep
can be enabled or disabled from the “Timing Parameters” menu described above.

Note: APS units manufactured prior to March 2014 are not fitted with a beeper.

You can postpone the switch off and restart the countdown timer by tapping the screen. To
disable the automatic switch off, set the time to “Infinite”.

Hint: If the APS about to turn off and you want to keep it on, touch the screen to postpone
the shutdown then touch the Home screen and touch Stand Alone, Enable.

4.5 LIMITS

The “Limits” menu allows you to set maximum (High) and minimum (Low) limits on the
input voltage for each phase to protect the equipment connected to that phase. If these
limits are exceeded, the input voltage display for that phase turns red and the outputs
connected to that phase will be switched off and their status indicators also turn red.