Use the following instructions to convert an H*42DF* for Rear Vent use:

1. Remove the Rear flue cover and gasket (5" and 8") on the flue

outlet, as shown in Figure 9.

2. Next, Remove the Top flue collar's (5" and 8") on the flue outlet,

as shown in Figure 9.

3. Install the (removed) Rear flue cover and gasket material, to the

Top vent outlet. Fasten the cover with included hardware, as

illustrated Figure 9a.

4. Install the (5" and 8") collars to the rear vent outlet using the

included hardware, as illustrated Figure 9a.

5” Inner Flue Collar

8” Outer Flue Collar

Flue Gasket

Flue Cover Plate

Montigo supplies a variety of direct venting and termination options.

The direct vent termination location MUST be selected such that

it is the highest point in the venting assembly. It should also be

selected such that it provides the shortest vent run possible. Should

it be impossible to ensure that the termination is the highest point

or to meet the venting guidelines laid out below please contact your

Montigo dealer to discuss power venting options.

NOTES FOR PLANNING VENTING:

„

Venting originates from the unit through the top or through

the rear

„

Venting can terminate through the roof or through an
exterior wall
.

„

Refer to Appendix A -Termination Locations to ensure the

planned termination location is acceptable.

„

Once the termination location has been established, refer

to the appropriate section for installation details.

„

All fireplaces shipped from the factory are Top vent.

„

Silicone application is NOT required when joining Montigo

vent pipes and components.

See Section 3-1 for converting the unit from top vent to rear vent.

NOTE: Air Baffle is shipped open. If you are top venting the air baffle

should be closed following these steps:

Figure 6. Air baffle in open position.

Figure 7.

Push the air baffle inward as far as possible and screw the air

baffle closed.

Figure 8. Air baffle in closed position

Note: Images are shown without screens for clarity purposes. However,

your fireplace should not be operated without proper installation of

screens.