XG0817 - 030412

„

If you cannot reach your gas supplier, call the Fire Department.

C. Use only your hand to push in or turn the gas control knob.

Never use tools. If the knob will not push in or turn by hand,

don't try to repair it, call a qualified service technician. Force

or attempt to repair may result in a fire or explosion.

D. Do not use this appliance if any part has been under water.

Immediately call a qualified service technician to inspect the

appliance and to replace any part of the control system, and

any gas control which has been under water.

a. This appliance has a pilot which must be lighted by hand.

When lighting the pilot, follow these instructions exactly.

B. BEFORE LIGHTInG smell all around the appliance area for

gas. Be sure to smell next to the floor because some gas is

heavier than air and will settle on the floor.

what To Do If You Smell Gas:

„

Do not try to light any appliance.

„

Do not touch any electrical switch; do not use any phone in

your building.

„

Immediately call your gas supplier from a neighbour's phone.

Follow the gas supplier's instructions.

To Turn Off Gas To Appliance:

3. Push in gas control knob slightly and turn

clockwise to

"Off". Do not force.

4. Replace the lower Horizontal access panel.

1. Turn off remote switch.
2. Lift out the lower Horizontal access panel.

with Continuous Pilot

with American Flame Electronic Ignition

For Your Safety - READ BEFORE LIGHTING:

Lighting Instructions:

1. STOP! Read the safety information above on this label.
2. Lift out the lower Horizontal access panel.
3. Push in gas control knob and turn clockwise

to "OFF."

4. Wait five (5) minutes to clear out any gas. Smell for gas,

including near the floor. If you then smell gas, STOP! Follow

"B" in the safety information above on this label. If you don't

smell gas, go to the next step.

5. Locate pilot burner (See illustration at right.) and follow steps

below.

6. Turn knob on gas control counter clockwise

to "PILOT."

7. Push in gas control knob completely and hold. Light with Piezo

Igniter button. Continue to hold the control knob in for about

(1) minute after the pilot is lit. Release the knob and it will pop

back up. Pilot should remain lit. If it goes out repeat steps 3

through 8.

„

If knob does not pop up when released. Stop and immediately

call your service technician or gas supplier.

„

If the pilot will not stay lit after several tries, turn the gas control

knob to "OFF" and call your service technician or gas supplier.

8. Push in gas control knob and turn counter-clockwise

to

"ON."

9. Replace the lower Horizontal access

panel.

10. Turn on remote switch to ignite fire.

nOTE: Gas control knob cannot be turned from "PILOT" to "OFF"

unless knob is pushed in slightly. Do not force.