Figure 3.

Framing dimensions (without Optional surround). Must be back-

framed as shown in Figure 2 below.

Installing The Fireplace
The fireplace may be installed in a location that maintains clearances to

ALL exterior furniture, appliances and other exterior equipment. Safety,

as well as efficiency of operation, must be considered when selecting

the fireplace location. Try to select a location that does not interfere with

foot traffic, has adequate ventilation, and offers an accessible pathway

for ventilated gasses.

Backframe Min. 38"

both sides Typical

41"

Surrounding construction

(bottom, sides and top) must

be non-combustible materials,

metal studs, concrete board

and concrete, brick, or stone.

Existing Co

mbustible Stru

ct

ur

e

40”

41”

23 7/8”

38”

36”

Combustible

materials

Backframe Min. 38"

both sides Typical

41"

Surrounding construction

(bottom, sides and top) must

be non-combustible materials,

metal studs, concrete board

and concrete, brick, or stone.

1" clearance

to corners only

1” Clearance to

combustibles to sides

ot Unit

Framing:

For Fireplace without the Optional Stainless steel

surround.

MODEL

Top

Header

Sides

Floor

Mantel

Ceiling

H*38VO-ST

36" 36" 12"

0"

24" 48"

Clearances

When installing a shelf over the top of the fireplaces, the following
guidelines must be adhered to: