Installation, Warning – Montigo H38SVO-ST User Manual

Page 7

Advertising
background image

H*38VO-ST Outdoor Gas Fireplace

Page 7

XG0817 - 030412

WARNING!

When this appliance is installed directly on exterior carpeting, tile

or any combustible material other than wood flooring, it must be

installed on a metal or wood panel extending the full width and

depth of the appliance.

Follow Figures 4,5 (wall installation) and Figure 3 (MIN size enclosure

for patio or other contemporary installation) to frame around the fireplace

chassis.
Note: ONLY Non-combustible materials must be used in construction

of the enclosure. (top, bottom and sides). Steel studs in combination

with concrete, rock, or stone finishing materials, are acceptable. See

Figures 3, 4 and 5.

Figure 4.

Back framing dimensions. (without Optional surround)

Figure 5.

Framing dimensions (without Optional surround). Distance from

Existing Structures.

Existing Co

mbustible Struct

ur

e

Backframe Min. 38"

both sides Typical

41"

Surrounding construction

(bottom, sides and top) must

be non-combustible materials,

metal studs,c oncrete board

and concrete,b rick, or stone.

24” Min.

WARNING!

When covering the upper metal portion of the fireplace with a non-

combustible material Please note: The decorative facing materials

may be subject to temperatures in excess of 350° F. This should be

considered when selecting facing materials.

Figure 6. non-combustible mantles and facings.

Backframe Min. 38”
both sides Typical

41”

Surrounding construction
(sides and top) must be
non-combustible materials,
metal studs,c oncrete board
and concrete,brick, or stone.

Non combustible

facing

Top of Fireplace

Header

42

39

36

33

30

27

24

21

18

15

12

9

6

3

1

Non combustible

Installation

Fireplace Facing
When selecting the finish material for your fireplace, it is important to

remember the following: THE LOwER GaS COnTROL PanEL MUST

nOT BE OBSTRUCTED In anY waY - to do so restricts the air supply

for the control compartments and heat exchanger it also prevents

access for servicing controls.
Decorative facing must not extend past the fireplace opening at all,

because it will interfere with the access to retainers for removal of

glass door.

Advertising
This manual is related to the following products: