See pages 13 to 14.

CAUTION!

„

Fireplace gas control must be in the “OFF” position and pilot

and main burners extinguished when cleaning appliance with

a vacuum.

„

Doors can get very hot. Handle only when cool.

General

„

Have the fireplace and installation inspected yearly. The

inspection must include, but is not limited to, the following:

„

A visual check of the entire vent system and termination.

„

An inspection of the explosion relief flappers and the door

gaskets to ensure a proper seal.

„

An inspection of the burner, vent run, and primary air openings.

„

An inspection of the gas valve, gas components, and pilot

flame. For your convenience a 1/8" manifold pressure tap is

supplied on the gas valve for a test gauge connection.

„

Ensure proper log placement as per this manual.

„

Inspection of all optional equipment; fans, thermostats, etc.

„

For natural Gas this appliance requires a minimum inlet pressure

of 5.5" W.C. and a manifold pressure of 3.5" W.C.

„

For Propane Gas this appliance requires a minimum inlet

pressure of 11" W.C. and a manifold pressure of 10" W.C.

„

Always keep the fireplace area clear and free of combustible

materials, as well as gasoline and other flammable vapours

and liquids.

„

Do not use this appliance if any part has been under water.

Immediately call a qualified service technician to inspect the

appliance and to replace any part of the control system and any

gas control which has been under water.

Cleaning

When the fireplace is first activated, there may be some smoking and

a visible film may be left on the glass. This is a normal condition, and is

the result of burning of protective coatings on new metal.

„

Glass must be cleaned periodically to remove any film (which is

a normal by-product of combustion) which may be visible. Film

can easily be removed by removing the door, as shown on Page

20. Handle the door carefully, and clean it with non-abrasive

glass cleaners. One of the most effective products is Kel Kem.

„

Silicone seals on inner door during initial firing will "off gas",

leaving a visual deposit of a white substance on combustion

chamber walls. This can easily be removed using normal

household products.

„

Use a vacuum cleaner or whisk broom to keep the control

compartment, burner, and firebox free from dust and lint.

„

Logs may be cleaned periodically with a vacuum to remove soot

or other contaminates.

Burner Adjustment
The H-Series VOST is equipped with an adjustable burner, allowing

you to raise or lower the flames. To adjust the flames, locate the black

knob marked 'Hi-Lo', in the centre of the gas control valve (See Figure

11). The front burners are not adjustable.

„

To raise the flame height, turn the black knob (located behind the

lower trim) counterclockwise.

„

To lower the flame height, turn clockwise.

Figure 12. 'Hi-Lo' Adjustment on the H-Series VO-ST gas valve.

'Hi-Lo' Adjustment Knob

Gas Control Knob

(Shown in "Pilot" postion.)