Maintenance, Gas control valve, Pilot burner adjustment – Montigo H38SVO-ST User Manual

Page 16: Troubleshooting

Advertising
background image

H*38VO-ST Outdoor Gas Fireplace

Page 16

XG0817 - 030412

Gas Control Valve

Manifold Pressure

Test Connection

Pilot Adjustment Screw

Inlet

Pressure

Power

Generator

Wall Switch

Figure 33.

Sit Nova 820 gas valve

.

Pilot Burner Adjustment

1. Locate Pilot Adjustment Screw. (See figure 33.)
2. Adjust pilot screw to provide properly sized flame as shown in

figure 34).

3. After installing or servicing, leak test with a soap solution with main

burner on. Coat pipe and tubing joints, gasket etc. with soap solution.

Bubbles indicate leaks. Tighten any areas where the bubbles appear

until the bubbling stops completely.

Figure 34.

Pilot Burner.

If your fireplace still does not operate correctly, consult your dealer or

the manufacturer.
all service and repairs should be performed by a qualified agency.
All spare parts, optional fans, and optional trim finishes are available

from your local dealer or the manufacturer.

Troubleshooting

Troubleshooting

The following is a troubleshooting chart of possible problems:

PROBLEM

CORRECTIVE aCTIOn

Noisy Pilot Flame

Locate pilot adjustement screw on

gas control valve. Flame is decreased by

turning adjustment screw clockwise.

Pilot won’t ignite

Disconnect remote wires and try to

light pilot. If pilot now works, remote

connections are faulty. Check wiring

diagram figure

33.

Main burner will

1. Check wiring (see figure 33).

not light

2. Check wall switch for proper

connection.

Maintenance