Installation, Warning – Montigo H38SVO-ST User Manual

Page 8

Advertising
background image

H*38VO-ST Outdoor Gas Fireplace

Page 8

XG0817 - 030412

WARNING!

Use Montigo Part No. #HSIT07 Water-tight electrical box, or

equivalent equipment. Ensure the box is installed in a dry location

and avoid any moisture.
If you install 115V Wire, ensure you use Ground fault breakers.

Also avoid any moisture near or around the 115V Circuit.

Installing The Remote Switch (H(L)VO-ST)
The H38 SVO's gas valve, located behind the lower trim, may be

connected to a wall switch. The valve generates its own power on a

millivolt circuit. Use only low voltage wire, and DO nOT connect

any external power to it.
Refer to Figure 4 for wiring requirements.
note: The switch location must not exceed 30' from the fireplace.

Figure 7. Wiring for the H(L)38VO-ST (N,L)E Honeywell gas control and pilot.

Figure 8. Standing Pilot Diagram (H(L)38VO-ST)

Honeywell (Q3450)

Pilot Assembly

Pilot Electrical

Harness Connector

Honeywell Gas

Control (SV9501M)

Gas Control

Connector

Wall

Switch

Water tight

Electrical box

White

Black

Source 110V

Distribution

Panel

Power
Generator

Wall Switch

Manifold Pressure
Test Connection

Inlet Pressure

Pilot Adjsutment Screw

Installation

Section 3: wiring

Advertising
This manual is related to the following products: