Selection of components and details of venting layout should adhere

to the following guidelines:

Vent terminations must not be recessed in walls or siding.

For Heat Shield requirements see page 16.

Once the proposed venting layout has been determined refer to

either Figure 12, 12a, 14, or 14a to ensure the layout is acceptable.

Wall Mounted Terminations: TOP VENT

All dimension lengths for vertical or horizontal runs are measured

from center of the vent pipe.

Venting runs must fall within the limits set by the venting graphs,

see Figure 12 or 12a.

The Venting Graph
Measure the vertical height from the fireplace hearth to the centre of

the termination and the horizontal run from the fireplace flue collar to

the wall flange of the termination. Plot on the Venting Graph Figure 12

or 12a with an 'X'.
If the 'X' falls on or above the top boundary of the shaded area, the

installation is acceptable.
Example A: (Acceptable Installation)

If the vertical dimension from the hearth is 126" and the horizontal

run to the wall flange of the vent termination is 138", this would be

an acceptable installation.

Example B: (Unacceptable Installation)

If the vertical dimension from the hearth is 36" and the horizontal

run to the wall flange of the vent termination is 84", this would

NOT be an acceptable installation�

Example C: (Unacceptable Installation)

If the vertical dimension from the floor of the fireplace is 60" and

the horizontal run to the wall flange of the vent termination is 144",
this would NOT be an acceptable installation�

Figure 12� H38C* or HL38C* Top Vent Venting Graph for wall mounted

terminations.

Figure 13a. H38C* or HL38C* Top Vented, wall mounted installation

with one 90° bend. The vent run must comply with Venting Graph for

Top vent, wall mounted terminations, Figure 12.

Figure 13

HP38C* Top Vent Venting Graph for wall mounted

terminations.

Figure 12a� HP38C* Top Vented, wall mounted installation with one 90° bend.

The vent run must comply with Venting Graph for Top vent, wall mounted

terminations, Figure 12a.

46”

A

C

B

.

Unacceptable vent run

within shaded area.

Acceptable vent run

within non-shaded area.

18”

If your installation does not

fall within the venting graph

parameters, please contact a

local Montigo dealer for Power

Venting options.

59”

A

C

B

Unacceptable vent run

within shaded area.

Acceptable vent run

within non-shaded area.

18”

If your installation does not

fall within the venting graph

parameters, please contact a

local Montigo dealer for Power

Venting options.

Heat

Shield

Termination

Hearth

Exterior

Wall

59” Min.

18” Max

Flex of Rigid

section

Heat

Shield

Termination

Hearth

Exterior

Wall

46” Min.

18” Max

Flex section