H*38DF-CLCR Corner Gas Fireplace

Installation

Figure 14. H38C* & HL38C*

Rear Vent Venting Graph for wall mounted

terminations.

Figure 15� H38C* & HL38C* Rear Vented, wall mounted multi-elbow

termination installation. The vent run must comply with the Venting Graph

for Rear vent, wall mounted terminations, Figure 14.

Wall Mounted Terminations: REAR VENT
NOTE: REAR VENT APPLICATIONS MUST HAVE A 59" VERTICAL

RISE� THEY CANNOT TERMINATE STRAIGHT THROUGH THE

WALL, see figure 14 or 14a.

All dimension lengths for vertical or horizontal runs are measured

from center of the vent pipe.

Venting runs must fall within the limits set by the venting graphs,

see Figure 14 or 14a.

Fireplace must be converted to Rear Vent configuration prior to

running vent, see Figure 8 and 8a.

The Venting Graph

Measure the vertical height from the fireplace hearth to the centre of

the termination and the horizontal run from the fireplace flue collar to

the wall flange of the termination. Plot on the Venting Graph Figure 14

or 14a with an 'X'.
If the 'X' falls on or above the top boundary of the shaded area, the

installation is acceptable.
Example A: (Acceptable Installation)

If the vertical dimension from the hearth is 84" and the horizontal

run to the wall flange of the vent termination is 48", this would be

an acceptable installation.

Example B: (Acceptable Installation)

If the vertical dimension from the hearth is 108" and the horizontal

run to the wall flange of the vent termination is 108", this would be

an acceptable installation.

Example C: (Unacceptable Installation)

If the vertical dimension from the floor of the fireplace is 66" and

the horizontal run to the wall flange of the vent termination is 90",

this would NOT be an acceptable installation�

Figure 15a� HP38C* Rear Vented, wall mounted Multi-elbow termination

installation. The vent run must comply with the Venting Graph for Rear vent,

wall mounted terminations, Figure 14a.

Figure 14a� HP38C* Rear Vent Venting Graph for wall mounted terminations.

42” Max.

59” Min.

18”

Max.

26”Min.

33”

Hearth

Flex or Rigid

Section

18”

59”

A

C

B

If your installation does not

fall within the venting graph

parameters, please contact local

Montigo dealer for Power

Venting options.

Unacceptable vent run

within shaded area.

Acceptable vent run

within non-shaded area.

59”

A

C

B

64”

Acceptable vent run

within non-shaded area.

Unacceptable vent run

within shaded area.

If your installation does not

fall within the venting graph

parameters, please contact local

Montigo dealer for Power

Venting options.

64” Max.

59” Min.

18”

Max.

Flex or Rigid

Section

26”

Min.

33”

Advertising
This manual is related to the following products: