H*38DF-CLCR Corner Gas Fireplace

Installation

Section 6: Finishing

Figure 22. Combustible mantles and facings

Mantels & Surrounds
NOTE:
National Canadian Gas Association mantel test requirements

are for fire hazard prevention to combustible materials.
New technology, to meet consumer and government demands for the

wise use of energy, has prompted us to manufacture many models of

fireplaces which are hot, fuel and energy efficient.

Finishing Around the Fireplace
Combustible mantels and mouldings may be safely installed over the

top and on the front of the fireplace provided that they do not project

beyond shaded area shown in Figure 22�

Fireplace Facing
When sizing the finish material for your fireplace, it is important to

remember the following: THE OPENING MUST NOT BE OBSTRUCTED

IN ANY WAY - to do so restricts the air supply for the control

compartments and heat exchanger it also prevents access for

servicing controls�
The face of the fireplace may be painted to match the room decor,

provided you use a heat-resistant paint. Decorative facing must not

extend past the fireplace opening at all, because it will interfere with

the access to retainers for removal of glass door.

We recommend careful consideration be given to the effects of elevated mantel

temperatures which may be in excess of product design, for example: candles, plastic

or pictures. This can cause melting, deformation, discoloration or premature failure of

T.V. radio, and other electronic components.

CAUTION

Figure 23� Combustible surrounds.

Side wall clearances are 3". Combustible surrounds may be installed

with 3" clearance to the side of the fireplace as shown in Figure 23.

When covering the upper metal portion of the fireplace, (as shown, Fig.21)

with a non-combustible m aterial, P lease

Note: The decorative facing

materials may be subject to temperatures in excess of 250° F. This should

be considered when selecting facing materials.

CAUTION

Combustible

Construction allowed

in shaded area

Top of fireplace

4” Nailing flange

Combustible Facing

Material

or Non-combustible

Horizontal Run (in)

Vertic

al

Run (in

)

Combustible header

Steel Stud Construction

allowable in grey area

Note: Images are shown without screens for clarity purposes. However,

your fireplace should not be operated without proper installation of

screens.

WARNING:

An inspection of the explosion relief flappers and door

MUST be made prior to lighting the fireplace. A faulty seal

on the door gasket and/or explosion ports will result in

products of combustion leaking into the living space and

may result in carbon monoxide poisoning.

WARNING

Do not place any materials or objects on top of the

valve blind. Doing so could result in failure of door

relief system or heat dissipation.

4” Nailing Flange

Drywall/Sheetrock

3”

Header