Installation, Wiring installation – Montigo LDVPV47 User Manual

Page 10

Advertising
background image

Page 10

LDVPV47 Linear Power Vent System

XG0750 - 112911

Installation

Figure 10. Wiring schematic for the Post Purge Control Module.

Wiring Installation

Upper Casing of Fireplace

Strain Relief

Wall Switch

Limit Switch

Air Proving Switch

Fuse

G

L2

L1

Bk

Bl

Bl

Bk

Bk

Bk

Bk

TDR

TDR Coil

R

R

R

W

W

W

W

W

Transformer

Strain Relief

115V

24V

Gas Control Connector

Motor

BX Conduit

Main Junction Box

Receptical

To 115V AC Supply

Legend

Denotes Line Voltage

Denotes Low Voltage

Denotes Wire Connector

Advertising