You must read and understand this manual prior to installation, operation or

troubleshooting this appliance. Please retain this owner’s manual for furure reference

and maintenance.

NOTICE

LDVPV47 Linear Power Vent System

Introduction

XG0750 - 112911

General Information

This installation guide covers installation of the Linear Power Vent System

only. This system is designed to allow installation of gas fireplaces that

cannot be done with a standard Direct Vent gas fireplace installation.
Specifications and instructions pertaining to your chosen fireplace must

be followed. Please read this Installation Operation and Maintenance

Instructions carefully before operating this equipment.

Standard Series (4"/7" dia.) Termination System:

LDVPV47 - Linear Power Vent System

Pre/Post Purge Control Box

RHSIT05 -Control module, provides pre/post purge. (HSI System)

ECB-007 Post Purge control box (IPI System)

Power Cord Harnesses:

LPVH10 -10 foot power cord and harness

LPVH20 -20 foot power cord and harness

LPVH30 -30 foot power cord and harness

LPVH40 -40 foot power cord and harness

LPVH50 -50 foot power cord and harness

LPVH60 -60 foot power cord and harness

LPVH70 -70 foot power cord and harness

LPVH80 -80 foot power cord and harness

Selecting and Installing the Fireplace

The Linear Power Vent System must only be used with a Montigo Direct

Vent Fireplace. When selecting a gas fireplace for use with the Linear

Power Vent System, take into consideration the various requirements and

limitations in the venting installation section of the Model's manual:

Models Must Be Equipped with Electronic Ignition

(HSI/IPI)
Only models equipped with an electronic ignition system may be

installed with the Linear Power Vent System. This system allows for

greater flexibility on venting requirements. For example downward

vertical vent runs are possible with an HSI/IPI system, as outlined in

the Venting Section.
All fireplaces with 5"/8" venting must be reduced to 4"/7" venting

in order to be used with the Linear Power Vent System.

Before You Begin

„

Minimum clearances of 1" from vent to all combustible materials

must be maintained.

„

The LDVPV must only be installed with Montigo venting

components. The LDVPV may be used with any of the available

Montigo terminations.

„

In order to maintain the power vent system integrity all 4"

and 7" venting connections must be fastened with three

self tapping screws.

„

Installation of the LDVPV must comply with this manual, and be

completed by a qualified professional.

„

Plan the layout of the installation's venting run before starting

the installation.

„

The MAXIMUM total allowable length; Refer to Linear Power

Vent Installation Section, Page 4-6.

„

Downward venting is allowable. Please refer to Page 5 for a

table and illustrations regarding the limitations of this type of

installation.

„

Minimum length of straight pipe between the Fireplace and the

Power Vent is: 2 feet

„

Access / Service Panel, must maintain 1" clearance. Minimum

30% free air must be supplied to the motor.

„

Disconnect the power supply when installing and/or

servicing the fireplace or the power vent system.

When cold air enters warm building interiors, primarily at the air intake end,

condensation may occur on the exterior of the flex pipe. To limit condensation, install

insulation over the last 20 feet of flex pipe. Sloping the last 20 - 0 feet of flex pipe

downward to the exterior of the building may also aid in eliminating condensation.

Ensure the termination is securly fastened and is sealed to the flex pipe. Fasten the

termination to building exterior with water tight sealant and appropriate fasteners.

CAUTIO N

Ensure perforated air holes in the new pipe adapter / restrictor are not covered

when installing new pipe connection.

CAUTION

Due to high operating temperatures, this appliance should be located out of traffic &

away from furniture and draperies.

Children and adults should be alerted to the hazards of the high surface temperature,

which could cause burns or clothing ignition.

Young children should be carefully supervised when they are in the same room as the

appliance.

Clothing or other flammable materials should not be placed on or near the appliance.

CAUTION