LDVPV47 Linear Power Vent System

XG0750 -112911

Installation

Section:

Installation of Pipe Diluter

The Installation of the LDV Air Circulator Pipe Reducer on your fireplace:

Model No's. that use 4" /7" Vent
1. Install the Pipe Diluter as shown below.

Figure 2a. Installation of 4" / 7" Flue Reducer.

Existing 4" Flue Adapter

Top of Fireplace

Fllue Diluter Collar

Slide Reducer

over 4" Flue

Adapter

Venting Installation

The Internal Power Vent must be installed with a gas fireplace equipped

with an electronic ignition system. When installing the venting, the

installation must adhere to the Venting Installation Section in the

fireplace's Installation Operation and Maintenance Instructions, as well

as the following guidelines:

„

Ensure that the planned termination location is acceptable as

shown in Appendix A.

„

Minimum of 2 feet of straight pipe before the power vent.

Installation of Pipe Reducer & Diluter

The Installation of the LDV Air Circulator Pipe Reducer on your fireplace:

Model No's. that use 5" /8" Vent
1. Install the Pipe Reducer & Diluter as shown below.

Figure 2b. Installation of 5"/8" Flue Reducer.

Existing 4" Flue Adapter

Top of Fireplace

Flue Reducer / Diluter

Slide Reducer/

Diluter over 4"

Flue Adapter

8" to 7" Reducer

See page 11 for detailed part numbers.

See page 11 for detailed part numbers.

Ensure perforated air holes in the new pipe adapter / diluter are not covered

when installing the new pipe connection.

CAUTION