Operation - model md44-dv-i, With honeywell intermittent pilot, For your safety - read before lighting – Montigo MD44 DV User Manual

Page 14: Lighting instructions

Advertising
background image

Part No. XG0120

Page 14

MD44-DV Direct Vent Vented Fireplace

Operation - Model MD44-DV-I

with Honeywell Intermittent Pilot

MD44-DV-I

For Your Safety - READ BEFORE LIGHTING:

A. This appliance is equipped with an ignition system

that lights the pilot burner automatically. Do not
attempt to light the pilot by hand.

B. BEFORE LIGHTING smell all around the appliance

area for gas. Be sure to smell next to the floor
because some gas is heavier than air and will settle
on the floor.

What To Do If You Smell Gas:

n

Do not try to light any appliance.

n

Do not touch any electrical switch; do not use any
phone in your building.

n

Immediately call your gas supplier from a
neighbour's phone. Follow the gas supplier's
instructions.

n

If you cannot reach your gas supplier, call the Fire
Department.

C. Use only your hand to push in or turn the gas control

knob. Never use tools. If the knob will not push in or
turn by hand, don't try to repair it, call a qualified
service technician. Force or attempt to repair may
result in a fire or explosion.

D. Do not use this appliance if any part has been under

water. Immediately call a qualified service technician
to inspect the appliance and to replace any part of the
control system, and any gas control which has been
under water.

Lighting Instructions:

1. STOP! Read the safety information above on this

label.

2. Remove lower brass trims.

3. Turn switch on the gas control to OFF".

4. Wait 5 minutes to clear out any gas. If you smell gas,

STOP! Follow "B" in the safety information above on
this label. If you don't smell gas, go to the next step.

5. Turn switch on the gas control to "ON". NOTE: This

unit is equipped with an ignition system that lights the
pilot burner automatically. Do not attempt to light the
pilot by hand.

6. Turn on wall switch.

7. Replace lower brass trim.

8. If the fireplace does not operate, follow the instructions

"To Turn Off Gas To Appliance" and call your service
technician or gas supplier.

Gas

Inlet

Gas Control Switch
Shown in "Off" Position

To Turn Off Gas To Appliance:

1.

Turn off remote switch.

2.

Remove lower brass trim.

3.

Turn the switch on the gas control to "Off".

4.

Flip up horizontal trim.

WARNING:

If you do not follow these instructions exactly, a fire or explosion
may result causing property damage, personal injury or loss of life.