Rear Vent Venting Runs

The MD44-DVRV has three possible installations:

1. Straight Installation.

The height from the hearth to the center of the termination is
33". MD44-DV Rear Vent versions are supplied with an 20"
extension pipe (PEXT-20) with female/female connections. For
shorter installations, cut the PEXT-20 to the desired length.

For extended installations, use the PEXT-20 section as supplied
for an 18" vent run.

Note:

For Rear Vent models, maximum horizontal run with no
vertical lift must never exceed 20".

3. 45° Corner Installation.

Use a 45° elbow, and a termination (and frame, if appropriate).

PEL-45

PTKO Series
Termination

Fireplace
Collar

Figure 16.

Straight installation.

Figure 17.

Corner installation.

4. Corner Installation - 45° or less.

Use a PFL-1 or -2 flex section (12" or 24" compressed length) and
a termination (and frame, if appropriate). Flex may be turned to
obtain desired degree of angle required but must not exceed 45°.
See diagram below:

Figure 18.

Flex installation.

PTKOFL-12/-18
Termination

Fireplace
Collar

Flue Collar

Heat Shield

EXT-18

Termination

PEXT-20

Rear Vent

PFL-1 / PFL-2