Operating the Nortec ME control software

Disifin

Disifin: when DISIFIN XL sachet(s) are added to the tank for disinfec-

tion, the conductivity in the tank will increase. This would cause a fault on

systems equipped with the optional conductivity monitoring.

With the function “Disifin” you can override the conductivity monitoring for

1 hour once you have added DISIFIN XL sachet(s).

Commissioning Reset: with this function you can reset the “Out of

Commissioning” message, which appears if the control unit has been

disconnected from the mains for more than 48 hours. After pressing on

the “Commissioning Reset” button a confirmation window appears where

the resetting must be confirmed.

Note: after resetting the control unit must be connected to the mains for

at least 15 minutes, otherwise the “Out of Commissioning” message ap-

pears on the next startup again.

Matrix Wash Over: with this function you can wash over the evaporative

cassette matrix. After pressing on the “Matrix Wash Over” button the wash

over cycle is automatically started.

Note: Use this function to wash over newly installed evaporative cassettes

to remove any dust and glue left after the manufacture of evaporative cas-

sette material. The wash over is mandatory for newly installed systems

with glass fibre type evaporative cassettes.

UV Bulb Reset: with this function you can reset the UV Bulb replacement

message after having replaced the UV bulb. This menu item appears only,

if this option is installed and activated..

Note: Resetting the UV Bulb replacement message without having replaced

the UV Bulb may lead to contamination of the system.

PureFlo Ag+ Reset: with this function you can reset the PureFlo Ag+

replacement message after having replaced the PureFlo Ag+ cartridge.

This menu item appears only, if this option is installed and activated.

Note: Resetting the PureFlo Ag+ replacement message without having

replaced the PureFlo Ag+ cartridge may lead to contamination of the system.

ME Service Reset: with this function you can reset the System Service

message after having performed a system service.

Note: Resetting the System Service replacement message without having

performed a system service may lead to contamination of the system.