Alarm flags – Olson Technology MUSCLE-EM55X User Manual

Page 64

Advertising
background image

OTOT-EM55X/XL Optical Transmitter Rev. x1

www.olsontech.com

63

Figure 51 — Setting the Event Mask for the Webserver and SNMP Interface of OTOT-EM55X

With this feature all warnings / alarms of the OTOT-EM55X can be either enabled or disabled by the user in relation to
the LED’s on the front panel, the Webserver status screen and SNMP interface. If the alarm/warning mask is applied a
notify message will be shown on the status menu screen.

Note: If the NEC software of a transmitter is upgraded to Rev. 1.9 or later, the OTOT-EM55X firmware might not sup-
port the alarm/warning flag mask, which means, that the LED’s on the front panel might not reflect the alarm/warning
masks.

Alarm Flags

Index

Flag

Description

0

TEC_HIGH_ALARM

Peltier current is higher than the alarm limit (Laser switched off)

1

OUTPUT_PWR_LOW_ALARM

Optical output power is lower than the alarm limit

2

RF_INPUT_LOW_ALARM

RF signal is lower than the alarm limit

3

OUTPUT_PWR_HIGH_ALARM

Optical output power is higher than the alarm limit

4

RF_INPUT_HIGH_ALARM

RF signal is higher than the alarm limit

5

OMI_OR_RFGAIN_LOW_ALARM

The calculated RF gain (if AGC on) or the calculated OMI (if AGC
off) is lower than the alarm limit

6

OMI_OR_RFGAIN_HIGH_ALARM

The calculated RF gain (AGC on) or the calculated OMI (AGC off) is
higher than the alarm limit

...

28

MODULE_TEMP_LOW_ALARM Module

temperature is lower than the alarm limit

29

MODULE_TEMP_HIGH_ALARM Module

temperature is higher than the alarm limit

30

RESERVED

Reserved for the NMS Controller (Do not use these bits)