3.2.8 Remote Mount Transmitter

Remote mount transmitters are provided with a single “L” bracket with 2 - ¼” mounting
holes. The bracket is secured to the transmitter by means of a large bolt with a knurled
knob for a head. To mount the bracket, first separate it from the transmitter housing and
attach it to the wall or other vertical surface. Cable from the sensor body is attached to the
transmitter using the center strain relief.

CAUTION

DO NOT drill holes in the main unit. Use only the openings that are provided. DO NOT cut the

remote cable. Coil excess cable at one end.

!

Insert

Mounting Bracket

Cable is supplied
already attached to
the sensor body.

Cable wires are
labeled with numbers
which correspond to
connection terminals
on the transmitter.