11451 Belcher Road South, Largo, FL 33773 • USA • Tel +1 (727) 447-6140 • Fax (727) 442-5699 • [email protected]
F-3200 Flow Meter Manual 05/14 - 0671-12 / 18325

Page A-1

Step 1
Remove rear cover.

Section 1: Removing the Transmitter
Before attempting to remote mount the transmitter, disconnect power at the source.

Step 6
Remove mounting screws from the
bottom of the enclosure. Screws do
not need to be fully removed.

Step 7
Carefully separate the electronics
enclosure from the sensor body.
As the two come apart, feed the
sensor wires through the opening
in the bottom of the enclosure.

Step 3
Remove power connector from
its socket. Remove wires from the
connector and set aside.

Step 2
Open rear compartment to
expose power connection.

Step 5
Remove electrode and coil wires
from connectors and set aside.

Step 4
Remove electrode and coil
connectors from their sockets.

Field Remote Mounting the Transmitter

Wiring Instructions