Gas connection, Warning, Danger – Permasteel PG-50601SRL(N) User Manual

Page 23: Connection for natural gas(ng) grills

Advertising
background image

20

WARNING

ƒ

Never insert any foreign objects into the valve outlet. It may damage the valve and
cause leak, leaking gas may result in fire, explosion, heavy body injury, or even death.

ƒ

Do not use this grill until leak tested.

ƒ

If you cannot stop a gas leak, close the LP tank valve IMMEDIATELY, call LP gas
supplier or the fire department.

DANGER

ƒ

NEVER store a spare LP tank under or near grill or in an enclosed area.

ƒ

NEVER fill the tank beyond 80% full. An overfilled spare LP tank is dangerous
because surplus gas may leak from safety relief valve. The safety relief valve on a LP
tank could activate to release gas and cause a fire.

ƒ

The spare LP tank must have safety caps installed on the LP tank outlet.

ƒ

If any gas leaks are found on the spare LP tank, immediately step away from the grill,
and call the fire department.

CONNECTION FOR NATURAL GAS(NG) GRILLS

CONNECTION FOR NATURAL GAS(NG) GRILLS

(Model: PG

(Model: PG

-

-

50601SRN):

50601SRN):

Your natural gas grill is factory built to operate using natural gas only. Never
attempt to operate your grill on gases other than the type specified on the grill
rating plates.

Your grill operates at 7 inch water column pressure.Verify supply pressure with

your local gas company. If supply pressure is different than 7 inch, contact a
certified plumber for assistance. Not for use with LP gas.

ƒ

BEFORE CONNECTION:

The natural gas hose and assemble are not supplied with this grill. Please
purchase a CSA approved Hose and assemble in local reputable dealer.

Hose and assembly are CSA listed for natural gas, manufacturer gas, mixed gas and

for liquefied petroleum and for LP Gas-Air mixtures on basis of 0.64 specific gravity
for 1000 BTU’s per cubic foot of gas at 0.3 inch water column pressure drop. Only
ANSI Z21.54 approved hoses should be used with this grill.

The appliance and its individual shut off valve must be disconnected from the gas
supply piping system during any pressure testing on that system at test pressures in
excess of 1/2 psi (3.5Kpa).

GAS CONNECTION