Memory, 20 tallies, Font – Pertech 5300 Series User Manual

Page 26: Rs232 interface, Usb interface, Hardware

Advertising
background image

Pertech

220321A

19

Font

There are three font options available in all control lan-
guages except the A470 Mode they are Standard - Com-
pressed - Expanded. The table below details each of the
font options pitch and column capabilities

Inkjet Font

Pitch
(Char/Inch)

Columns
(Char/Line)

Standard

16

40

Compressed

22.8

57

Expanded

13.2

33

The A470 control language has the following font capabili-
ties: 33, 36, 40, 44, 50, 57, 66 Characters Per Line

RS232 Interface

Baud Rate - Data Bits -Stop Bit - Parity and Flow control
settings are selectable through the confguration menu.
Flow control is designated as Hardware = DTR, DSR, or
RTS, CTS depending on the printer control language be-
ing used. Software fow control is Xon/Xoff.

USB Interface

Change the USB option to “Serial Number” for the USB
driver to assign serial numbers for each printer that is
installed. The Model number default selection allows for
a 5300 printer to be removed and a new 5300 printer to
be installed without the Operating System detecting and
installing a new driver.

Hardware

The Mechanism Model identifes the printers current
model setting, this parameter can only be adjusted with
the use of command codes. This parameter is set at the
factory and should not require change.
The option for Validation Clamp default to be changed
to the Open position is only available in the A470 mode
control language.
The time allowed for the user to insert a form is selectable
up to 15 minutes.
The Paper Low Stop can be set to enable or disable,
enable will notify the user via the led indicator when the
paper is out.
There are two options for the INK STATUS RESET set-
ting.
1. Automatic (Default Setting) - Allows for the user to
automatically reset the ink cartridge Dot Count Tally,
LOW INK LED and Command Status Notifcation for a
new cartridge. The cover must be opened and closed an
additional time after the old Ink Cartridge is removed and
before a new Cartridge is installed for the Status to clear.
2. Manual - LOW INK LED Status Notifcation will occur
when the Dot Count exceeds it preset limit for the car-
tridge. The Dot Count Tally must be reset via Confgura-
tion Menu to clear LOW INK LED Status.
Available Fixed Document stop settings are 1.75”, 1.63”
and 1.46” these are available in the one button confgura-
tion mode. The Confguration Utility allows the Document
Stop settings to be incrementally set between the .17”
and 1.75”. The validation print feld width is 2.5”, up to 14
lines of print @ 1.75” setting with Validation Lines Per inch
set at 8 LPI.

3 Inches

1 Inch

Print feld is 2.5” Wide

Center Justify

3.25 Inches

Print Zone

2 Inches for 6” Check

1.75”

1.63”

1.46”

Column Alignment is set at the factory and should not be
adjusted.

Advertising
This manual is related to the following products: