Model 526 contains 4 identical 24-bit up/down counters with enable and preload. The block
diagram of one of the counters is shown on Fig.2.

"1"

ECAP

SOFTWARE LOAD

PRELOAD BUFFER 0

UP/DOWN

POWER-ON RESET

CLKB

INTERNAL

INDEX

INDEX

.

.

.

"1"

CLK

D

Q

DATA BUS

CLKA

SOFTWARE RESET

RTGL

"1"

ICAP-

ENABLE

CLK

D

Q

CLK

D

Q

Q

COUNTER CORE

LOAD

ROLLOVER

LATCH

RTGL

INDEX^

ROLLOVER

CE

CLOCK

RCAP

CLK

D

Q

INDEXv

COUT

CLOCK MUX/
QUADRATURE
DETECTOR

PRELOAD BUFFER 1

RESET

INTERNAL/2

CLK

D

Q

"1"

ICAP+

ERROR

DATA BUS


Fig.2. Counter simplified block diagram.


See the description of Counter Mode register and Counter Control/Status register in the
Registers section for the implementation specifics.

Input Signals

The counter accepts the following input signals (connector J5):

CLKA – phase A of the encoder, or any clock signal in normal mode;

CLKB – phase B of the encoder;

INDEX – index signal of the encoder, or any digital signal;

CE – external count enable.

Signals CLKA, CLKB and INDEX could be either differential (RS-422), or single-ended. In case of a
single-ended signal the “+” input has to be used.

The clock source can be selected through the software. In quadrature mode the possible clock
sources are:

quadrature x1 (CLKA

counting up, CLKA

counting down);