Referring to the Model 32 or Model 33
schematic diagram, observe the 200 ohm
resistor that is connected between circuit
common and the counterclockwise con-
nection of each potentiometer. This resis-
tor prevents full attenuation. By replacing
this 200 ohm resistor with a 0 ohm
resistor or jumper strap, full attenuation
can be achieved.