2. CONSIDERATIONS FOR THE PLACEMENT OF THE LIFT (for standard Plasma Two
lift with 52" of lowering distance):

Vertical Clearance: Once the location of the plasma lift is determined, please verify that there is
sufficient space above the false ceiling to accommodate the lift, the screen, the optional ceiling closure,
and that nothing will interfere with their operation. The lift needs a minimum clearance of 41.75"
(106.04cm) of vertical height in the ceiling (supporting structure of the lift and spring loaded ceiling
closure system not included).- see figure 1.

Please keep in mind that the overall height of the lift as well as the lowering distance may
vary with the size of the plasma screen.
The inside clearance of the lift for the screen's height is
34" High (86.36 cm). Considering that the clearance above the screen should be at least 1" (2.54 cm),
and if you are using a 35" tall screen, the screen will extend below the lift's bottom frame by 1" .

Figure 1.

Figure 2.

Horizontal Clearance:

Depth of the lift:

14" Deep (top frame) x 5.375" Deep (bottom frame)- 35.56 cm x 13.65 cm- see
Figure 1. Note: The ceiling opening size is based on the bottom frame of the lift
(only part that travels through the ceiling opening). To determine the depth of
the ceiling opening, you will need to add the depth of the plasma screen and the
depth of the screen's mounting bracket. Important: If the plasma screen needs to
be tilted, this will also increase the overall depth of the ceiling opening.

Width of the lift:

29" Wide (bottom frame) x 36.75" Wide (top frame) - 73.66 cm x 93.34 cm -see
Figure2. The width of the ceiling opening will be based on the width of the
plasma screen- see Figure 2.

SVS PLASMA TWO LIFT INSTALLATION

Page 5 of 13

Advertising