ADDITIONAL INSTRUCTIONS FOR ATEX VERSION
The LTDR is suitable for applications with hazardous gas or dust atmospheres, for
applications requiring instruments of category 1/2G, 1/2D or 2G, 2D.
If the LTDR is installed and operated in hazardous areas, the general hazardous area
installation regulations IEC 60079-14, all relevant national, regional and local regulations
and standards, as well as these safety instructions must be observed.
The installation of electrical equipment in hazardous areas must always be carried out by
qualified personnel.
The approval certificate is the following:

0158 SEV 09 ATEX 0171 X

and the different markings:

II 1/2G Ex ia/d IIC T6

II 1/2G Ex ia/d IIC T6 Ga/Gb

II 1/2D Ex iaD/tD A20/21 IP68 T86°C II 1/2D Ex ia/t IIIC T86°C Da/Db

II 2G Ex ia d IIC T6

II 2G Ex ia d IIC T6 Gb

II 2D Ex iaD tD A21 IP68 T86°C

II 2D Ex ia t IIIC T86°C Db

14.1 Electrical data

Power supply (terminals 1 and 2): U = 12…30V DC

U

m

= 250 VAC

Analog output (terminals 3 and 4): I = 4…20mA

U

m

= 250 VAC

Switching output (terminals 5 and 6): U

s

= 0…U

U

m

= 250 VAC

14.2 Temperatures

CATEGORY 1/2G

Temperature class

Application

temperature

Ambient temperature

T1...T6 -20…+60°C

-40…+70°C

CATEGORY 2G

T6 -40…+85°C

-40…+70°C

T5 -40…+100°C

-40…+70°C

T4 -40…+135°C

-40…+70°C

T1…T3 -40…+150°C

-40…+70°C

CATEGORY 1/2D Y 2D

Max. sup. temperature: +86°C

-40…+70°C

14.3 Dimensions

Earth terminal

Cover locking screw