Figure 5. dip switch settings – Tecfluid LTDR Series User Manual

Page 7

Advertising
background image

7



red: indicates DIP switch position 8 which switches between measuring and
configuration mode. Only when DIP switch position 8 is on/1, LTDR can be
configured; configuration mode is indicated by the LED blinking alternately green and
red.
When DIP switch position 8 is off/0, LTDR is in measuring mode; indicated by the
LED blinking green.
It is only possible to enter the configuration mode when DIP switch positions 1 to 7
are off/0 before setting DIP switch position 8 to on/1; otherwise the LED is blinking red
to indicate an error



blue: indicates the DIP positions through which groups of functions are selected, e.g.
all functions related to the analog current output or the switching output

DIP SWITCH SETTINGS

DESCRIPTION

0

0

0

0

0

0

0

0 measuring

mode

0

0

0

0

0

0

0

1 configuration

mode

FUNCTION GROUP 1

ANALOG CURRENT OUTPUT

0

0

0

1

0

0

1

1

lower range value [4mA]; span 0%

0

0

1

0

upper range value [20mA]; span 100%

0

1

0

0

response time 0,5s (default)

0

1

0

1 response

time

2s

0

1

1

0 response

time

5s

FUNCTION GROUP 2

SWITCHING OUTPUT

0

0

1

0

0

1

0

1

lower threshold

0

0

1

1 upper

threshold

0

1

0

0 NC

0

1

0

1 NO

FUNCTION GROUP 3

DISTURBANCE SIGNAL SUPPRESSION

0

0

0

1

0

1

1

perform disturbance signal scan

0

0

1

0

disturbance signal scan: do not utilize

0

0

1

1

disturbance signal scan: utilize (default)

0

1

0

0

upper dead band: short (default)

single rod probe 30mm1
coaxial probe 0mm1

0

1

0

1

upper dead band: medium

single rod probe 190mm1
coaxial probe 160mm1

0

1

1

0

upper dead band: long

single rod probe 390mm1
coaxial probe 360mm1

1

0

0

0

amplitude threshold: low (default)

1

0

0

1

amplitude threshold: medium

1

0

1

0

amplitude threshold: high

1

1

0

0 coaxial

probe

1

1

0

1

Single rod probe

FUNCTION GROUP 4

RESET

0

0

0

1

1

0

0

1

reset to delivery configuration

FUNCTION GROUP 5

MEASURE PROBE LENGTH

0

0

0

1

1

0

1

1 measure

probe

length

1

DIP SWITCH POSITION

1

2

3

4

5

6

7

8