211

Switch Output

The All Sport 5000 series console has a switch that can be used to drive a number of different
devices. The switch can be configured to operate under different settings. The default
setting is 1-CLOCK= 0.

To display the switch setting that you want to select:

Press the number (0,1,2,3) key as a shortcut or use the left and right arrow keys to scroll to
the desired setting.

Press <YES> to select the new setting.

Press <NO> or the down arrow key to leave the switch setting and display the next prompt.

The possible settings for the switch output are as follows:

Setting

Result

0-DISABLED

SWITCH OUTPUT=n
0-DISABLED?

n = current setting

The switch remains open at all times and any external

devices are disabled.

1-CLOCK = 0

SWITCH OUTPUT=n
1-CLOCK =0?

n = current setting

In count down mode, the switch closes when the main

clock reaches zero and remains closed until a nonzero

value is entered.

In count up mode, the switch closes when the main

clock reaches the proper period, break, or overtime

length and opens when any other value is entered.

2-CLOCK STOP

SWITCH OUTPUT=n
2-CLOCK STOP?

n = current setting

The switch closes when the main clock is stopped and

opens when the main clock is running. External devices

are disabled when the main clock is running.

3-MAIN HORN

SWITCH OUTPUT=n
3-MAIN HORN?

n = current setting

The switch closes when the main horn sounds. This

could be when Auto Horn is enabled and the main

clock reaches zero or when <HORN> is pressed.