Switch output=n 0-disabled, Switch output=n 1-clock =0, Switch output=n 2-clock stop – Daktronics All Sport 5000 User Manual

Page 272: Switch output=n 3-main horn

Advertising
background image

Tae Kwon Do Operations

255

Press <

NO

> or the down arrow key to leave the relay setting and display the next

prompt.

The possible settings for relay output are as follows:

Setting

Result

0-DISABLED

SWITCH OUTPUT=n
0-DISABLED?

N = current setting

The relay remains open at all times and any

external devices are disabled.

1-CLOCK = 0

SWITCH OUTPUT=n
1-CLOCK =0?

N = current setting

In count down mode, the relay closes when the

main clock reaches zero and remains closed until a

nonzero value is entered.

In count up mode, the relay closes when the main

clock reaches the proper period, break, or overtime

length and opens when any other value is entered.

2-CLOCK STOP

SWITCH OUTPUT=n
2-CLOCK STOP?

N = current setting

The relay closes when the main clock is stopped

and opens when the main clock is running. External

devices are disabled when the main clock is

running.

3-MAIN HORN

SWITCH OUTPUT=n
3-MAIN HORN?

N = current setting

The relay closes when the main horn sounds. This

could be when Auto Horn is enabled and the main

clock reaches zero or when <HORN> is pressed.


Default Settings

Write the settings for this installation in the space (Custom) provided.

Setting

Default

Custom 1

Custom 2

Custom 3

Switch Output

1-Clock =0

Auto/Manual Timing

Auto

Round Length

(accessed by key)

3:00

Rest Length (accessed

by key)

1:00

Advertising