Operator’s manual df32, 6 programming – Watson-Marlow DF32 User Manual

Page 12

Advertising
background image

Operator’s manual
DF32

Rev.: 1.03 Date: 2007-03-12 Page 12 of 32

File:
DF32 OM 1.03 EN

6 Programming

6.1 Starting

DF32

When turning on the main switch, the display will show the following:

DF32 V1.1 (C) Flexicon’ 00

PRESS GO TO CONTINUE

Fig. 6.1


Press the <GO> key and the display will show the following:

FUNCTION NO.:

F 1: VOLUME (ml): 100.00

Fig. 6.2

The value shown in the status line will be the above or the last value used.

DF32 is now ready to be programmed.

6.2 Parameters

In the following, a parameter will be the value of a single function, for instance volume, velocity or
number of fills.

6.3 Programs

In the following descriptions, a program will be a complete set of parameters which together will
constitute the DF32 work instructions.

6.4 General information on the programming of DF32

DF32 is equipped with a battery in the memory and will therefore always remember the programmed
parameters, even if the main isolator is turned off.

The programming is done using functions, i.e. every operating parameter has its own function
number.

The programming is carried out by entering the function number followed by "ENT".

This will make the required function appear in the prompt line of the display and show the current
value or information of the function.
This value will automatically be overwritten when entering a new value.
After being entered, the new value will be shown in the prompt line. The new value is entered into the
computer by pressing "ENT".
The new value will be shown in the status line at once.

Example:
If a volume of 8.5 ml is required, the following must be entered:
<1>+<ENT>+<8>+<.>+<5>+<ENT>

Advertising