Westermo TD-22 User Manual

Page 40

Advertising
background image

41

6177-2203

Bit 3

Modem-to-modem flow control
0 =

Disabled (\G0) (Default.)

1 =

Enabled (\G1)

Bits 4-5

Reserved

Bit 7

Enable fallback to V.22 bis/V.22 (-Qn)
0 =

Disabled (-Q0)

1 =

Enabled (-Q1) (Default.)

S46 – V.42bis, Data Compression Control
136

Execute error correction protocol with no compression.

138

Execute error correction protocol with compression. (Default.)

S48 – V.42 Negotiation Action
0

Force LAPM connection.

7

Enable negotiation. (Default.)

128

Force action specified in S36.

Please also refer to S36.

S80 – Soft-Switch Functions (Stored directly in the E2 memory)
If switch SW2:1 is OFF, S80 will not be used
Bits 0

Selection of type of command
0 =

AT

1 =

V.25

Bit 2

Auto line quality and retain monitoring
0 =

No line monitoring or renegotiation (AT0)

1 =

Line monitoring or renegotiation (AT1)

Bit 3

Modem-to-modem flow control
0 =

Disabled (AT0)

1 =

Enabled (AT1)

Bit 4

MNP block or digit flow control
0 =

Disabled (AT0)

1 =

Enabled (AT1)

S82 – Break control for LAPM connections
3 – Break is sent immediately. Data in the buffer is stored
7 – Break is sent immediately. Data in the buffer is lost
128 – Break is buffered (Default.)

S86 – Call Failure Reason Code (Read only register, not stored with the AT&W command!)
This register is written with an indication of the error cause after a dialling error.
Default 0 {0..255}

S91 – PSTN Transmit Attenuation Level (Stored directly in the E2 memory)
Default 13 {0..15} dBm (Corresponding to 0 to -15 dBm transmit level.) Country dependant.

S92 – Fax Transmit Attenuation Level (Stored directly in the E2 memory)
Default 13 {0..15} dBm (Corresponding to 0 to -15 dBm transmit level.) Country dependant.

S95 – Extended Result Codes
Set by \V.
Default 0 {0..7}

S99 – Leased Line Transmission Level (Stored directly in the E2 memory)
Default 10 {0..15} dBm (Corresponding to 0 to -15 dBm transmit level.) Country dependant.